Huawei MA5600T and Huawei MA5603T are very common used, and the service board specifications are as below:
32-Channel ADSL2+ Service Board Specifications
Table 1 Specifications lists of 32-channel ADSL2+ service boards
H808ADIF
|
H808ADLE
|
H805ADLF
|
H808ADLF
|
|||
Applicable Line
|
ADSL2+ over ISDN
|
ADSL2+ over POTS
|
ADSL2+ over POTS
|
ADSL2+ over POTS
|
||
Physical Layer
Retransmission (G.INP)
|
No
|
No
|
No
|
No
|
||
ADSL2+ Bonding
|
No
|
No
|
No
|
No
|
||
INM
|
No
|
No
|
No
|
No
|
||
SELT
|
Yes
|
Yes
|
Yes
|
Yes
|
||
MELT
|
No
|
No
|
No
|
No
|
||
Annex Type
|
l
G.992.1 Annex B/J
l
G.992.3 Annex B/J
l
G.992.5 Annex B/J
|
l
G.992.1 Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
l
G.992.1
Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
l
G.992.1 Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
||
Flexible
Configuration Modes
|
Supports RFC2662 and RFC4706. (Users
with a super user account can log in to the system and run the switch adsl mode to command in
diagnose mode to switch between the configuration modes. The default
configuration mode is RFC2662)
|
|||||
Built-in Splitter
|
No
|
Yes (600-ohm pure
impedance splitter)
|
No
|
No
|
||
Temperature Query
and High-temperature Alarm
|
Yes
|
Yes
|
Yes
|
Yes
|
||
Automatic Power
Shutdown in Case of a High Temperature
|
No
|
Yes (Supported by
V800R009C00 and later)
|
No
|
Yes (Supported by
V800R009C00 and later)
|
||
64-Channel ADSL2+ Service Board Specifications
Table
2 Specifications lists of
64-channel ADSL2+ service boards
H802ADPD
|
H805ADPD
|
H802ADQD
|
H802ADKM
|
H80BADPE
|
H808ADPM
|
|
Applicable Line
|
ADSL2+ over POTS
|
ADSL2+ over POTS
|
ADSL2+ over ISDN
|
ADSL2+
|
ADSL2+ over POTS
|
ADSL2+ over POTS
|
Physical Layer Retransmission (G.INP)
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
ADSL2+ Bonding
|
Yes (Supported by V800R011C00 and later)
|
Yes (Supported by V800R009C00 and later)
|
No
|
Yes (Supported by V800R011C00 and later)
|
Yes (Supported by V800R010C00 and later)
|
Yes (Supported by V800R010C00 and later)
|
INM
|
Yes
|
Yes
|
No
|
No
|
Yes
|
Yes
|
SELT
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
DELT
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
MELT
|
No
|
No
|
No
|
Yes
|
No
|
Yes
|
Annex Type
|
l
G.992.1
Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
l
G.992.1
Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
l
G.992.3 Annex B
l
G.992.5 Annex B
|
l
G.992.3 Annex B/J
l
G.992.5 Annex B/J
|
l
G.992.1 Annex A
l
G.992.3
Annex A/L/M (EU32-EU64)
l
G.992.5
Annex A/M (EU32-EU64)
|
l
G.992.1
Annex A
l
G.992.3
Annex A/L/M/J (EU32-EU64)
l
G.992.5
Annex A/M/J (EU32-EU64)
|
Flexible Configuration Modes
|
Supports RFC2662, RFC4706, and TR165. (Users with a super user account
can log in to the system and run the switch adsl mode to command in diagnose mode to switch
between the configuration modes. The default configuration mode is RFC2662.
Considering the current development trend, it is recommended that you use
TR165, which is more flexible than the others)
|
|||||
Built-in Splitter
|
No
|
No
|
No
|
No
|
Yes (600-ohm pure impedance splitter)
|
No
|
Temperature Query and High-temperature Alarm
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Automatic Power Shutdown in Case of a High Temperature
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
Yes
|
For
more information, you can login www.huanetwork.com or feel free
to contact sales@huanetwork.com,
they will tell what you want. What’s more, Our HCIE headed technical team can
provide network design, products installation and configuration, trouble
shooting etc.
No comments: